Utility Simulator
Move the sliders to see how load, flow and operating conditions affect a cooling tower, screw air compressor and steam boiler, then use the full simulator below to compare all eleven plant utilities. All outputs are educational estimates, not control settings.
Costs show in both currencies. Replace the exchange rate with today's rate for your bills.
Within illustrative band
Air and water flow are sufficient for this illustrative load.
All 11 Utilities Simulator
Pick a utility, choose Simple or Complex mode and a plant size, set your country's tariffs, then download a report, CSV or printout of the scenario.
What the simplified models assume
The animated models at the top use these simplified assumptions. The cooling-tower example uses a 3 °C approach at 80% load, 80% fan speed and 100 m³/h circulating flow. Approach is scaled with load and simplified airflow/water-flow factors. Fan power follows a cubic speed relationship using a 15 kW reference. Wet-bulb temperature establishes the approximate thermodynamic cooling floor; this model omits fill condition, recirculation and detailed psychrometrics.
The compressor assumes 6.4 kW per m³/min at its reference point. Required production equals useful demand divided by one minus the leakage fraction. Filter differential and intake temperature apply simplified power penalties. It omits pressure-ratio curves, unloading cycles and compressor-specific control strategies. These assumptions are illustrative, not a promise of savings.
The boiler uses a 10 t/h reference and 2,778 kJ/kg illustrative steam enthalpy. Feedwater enthalpy is approximated by 4.186 times its Celsius temperature. Excess air and blowdown reduce estimated efficiency. Actual efficiency depends on fuel, pressure, feedwater chemistry and design; this model must never be used for combustion tuning. Daily cost equals estimated input power × running hours × entered energy tariff, shown side by side in US dollars and Pakistani rupees using the exchange rate you enter (default Rs 280 per US$; replace it with the current rate). For boilers, enter a fuel-energy tariff rather than an electricity price.
Each slider starts with a typical range. Use Adjust slider ranges to set your own lower and upper limits for larger or smaller plants, or type an exact value beside the slider. Outer limits keep the simplified formulas meaningful — for example leakage stays below 100% and flow above zero. The fixed reference sizes (15 kW fan, 10 t/h boiler) do not scale with the ranges, so very large settings show trends rather than plant-specific figures.
How the 11-utility simulator works
The full simulator estimates annual energy, fuel, water and CO₂ for each utility from the capacity, load, running hours and prices you enter. Simple mode uses typical efficiencies; Complex mode adds losses such as stack temperature, leakage, moisture and auxiliary power. Country tariffs are indicative starting values — replace them with your plant's actual bills. Results are screening estimates (about ±10–15%) and should be confirmed with metered data before any investment decision.
Guidance only. Follow manufacturer limits and site procedures; hazardous work requires qualified personnel.