Gas turbine heat-rate calculation: fuel basis, net output and performance diagnosis
Independent engineering sign-off is not claimed. Editorial standards & corrections
Calculate gas turbine net heat rate and electrical efficiency with declared fuel units, a worked LHV example and measurement-led performance checks.
Calculate, Understand & Investigate
In Calculators, choose “Gas turbine power plant”. Simple mode is free; Complex mode requires Professional access. Calculations support investigation, not equipment approval.
Define what performance you are comparing
Heat rate is fuel energy consumed per unit of electrical output. A lower value means less fuel per kWh on the same measurement basis, not necessarily higher available capacity. A turbine may have acceptable heat rate at reduced output while the process still lacks power. Separate these two questions before planning service.
Choose the generator or net-export boundary and document auxiliaries. Declare LHV or HHV, fuel reference conditions and the averaging period. A CHP installation also supplies heat: do not subtract that heat from fuel without naming the allocation method. Compare electrical heat rate and useful-heat utilisation separately.
Equations and variables
Fuel input Pf = mf × LHV / 3.6, where mf is fuel mass in kg/h, LHV is MJ/kg and Pf is kW thermal. Net efficiency η = Pnet/Pf as a fraction. Heat rate HR = 3,600/η in kJ/kWh. For metered energy over a period, HR = fuel energy in kJ / net electricity in kWh.
Volumetric gas metering requires heating value on the same declared volume reference. Convert compensated volume and calorific value together; actual m³ at line pressure cannot be multiplied by a normal-m³ heating value without correction.
Worked example: gross versus net output (illustrative)
Assume fuel consumption 720 kg/h at LHV 50 MJ/kg. Fuel input = 720 × 50 / 3.6 = 10,000 kW. Gross generation is 3,200 kW and included auxiliaries are 200 kW. Net output = 3,000 kW; net efficiency = 30%; net heat rate = 12,000 kJ/kWh LHV. Gross heat rate would be 11,250 kJ/kWh. Both describe the assumed plant but they are not interchangeable.
If the same fuel produces 2,800 kW net, heat rate becomes 12,857 kJ/kWh, about 7.14% higher. This comparison establishes a change in the assumed balance, not its cause or an expected turbine efficiency.
Build a defensible investigation
Synchronise fuel, electrical and ambient measurements. Separate startup, standby and stable loaded operation. Check fuel composition updates, meter compensation, auxiliary changes, inlet-filter loss and exhaust backpressure. Compare with OEM correction curves at load, ambient conditions and control mode, or matched periods where correction is unavailable.
A hot day, part-load operation and compressor fouling can all change observed output and heat rate. If ambient conditions differ, a raw percentage change cannot identify degradation. Review corrected capacity and heat-rate trends together with vibration, exhaust spread and event records. Industry 4.0 logging helps align evidence; it does not confirm a failed component.
Uncertainty, maintenance and safety
Fuel-flow and heating-value uncertainty directly affect input; electrical uncertainty affects the denominator. Report measurement accuracy and unexplained balance differences instead of assigning excessive decimal precision. Use the adopted acceptance-test method for guarantees rather than this simplified example.
Compressor washing, combustion tuning, fuel-system inspection and protection tests require OEM-supported procedures and qualified personnel. Do not change firing limits, disable trips or restart after a protective event from a heat-rate result. Gas, rotating machinery, hot exhaust and high voltage remain independent hazards.
Technical References & Further Reading
Background sources, not endorsements or a claim of independent review. Use the applicable edition, installed manual and authorised site procedure for actual work.
This guidance is general. Always follow the equipment manufacturer's manual and your site safety procedures. See our engineering disclaimer.