UTILITIES EXPERT · ENGINEERING REPORT

Air Compressor Inspection Report — 573567 — Fault Finder Summary

REPORT DETAILS

Report Name: Air Compressor Inspection Report

UTILITIES EXPERT — FAULT FINDER SUMMARY REPORT

Equipment title: 573567

Date: 27/10/2026, 14:08:34

Media: 573567.mp4 (video)

Operator note: Screw Air Compressor Air End Inspection

EQUIPMENT IDENTIFIED

Rotary Screw Air Compressor Air End

FINAL FINDING (confidence: HIGH)

The air end shows severe bearing failure and heavy oxidation (rust) on internal retaining plates. A high-pitched metallic whine and grinding sound are audible, indicating that the bearings have lost their integrity and are likely causing rotor-to-housing contact. Immediate overhaul or replacement of the air end is required before the unit is run again to prevent total seizure.

EVIDENCE OBSERVED

- Heavy orange-brown rust visible on rotor shaft retaining washers and bolt heads

- Evidence of dark, sludge-like oil contamination surrounding the bearings

- Visible displacement/excessive play in the bearing race

- High-pitched metallic whine/grinding noise consistent with high-speed bearing failure

SUPPORTING CAUSES

1. Moisture ingress and lubricant contamination [high]

Evidence: Extensive rust on the internal steel components and discolored, emulsified-looking oil residue.

Checks: Check the oil water separator and condensate drains for proper operation; Inspect the oil for water content via a crackle test or lab analysis

2. Bearing cage collapse or fatigue [high]

Evidence: The audible high-frequency whine and the visible misalignment of the shaft within the bearing housing.

Checks: Perform a manual rotation of the air end (unpowered) to feel for binding or rough spots; Check the service history for the last bearing replacement interval

3. Lubrication starvation or oxidation [medium]

Evidence: Dark, burnt-looking residues around the bearing bores suggesting high heat and oil breakdown.

Checks: Verify oil filter differential pressure and oil stop valve operation

READINGS TO CONFIRM

- What was the discharge temperature reading before the unit was opened?

- How many total run hours are on this air end?

- When was the last oil analysis performed and what were the moisture levels?

- Is the unit running in a high-humidity environment or frequently cycling on/off?

SAFETY

- Ensure full Lock-Out Tag-Out (LOTO) of the main power supply before touching internal components

- Verify the system is completely depressurized; check the local gauge on the sump tank

- Use protective gloves when handling components covered in degraded or contaminated lubricant

- Before executing any critical decision, discuss with your plant team. Invasive or live work only by qualified staff per the OEM manual.

Media quality: Clear and focused video of the air end internals with high-quality audio.

AI-assisted finding — verify on site before acting. https://utilitiesexpert.online